Breakthrough Microscope Enhances Detection Range for Cellular Observations

Researchers Kohki Horie, Keiichiro Toda, Takuma Nakamura, and Takuro Ideguchi of the University of Tokyo have built a microscope that can detect a signal over an intensity range fourteen times wider than conventional microscopes. Moreover, the observations are made label-free, that is, without the use of additional dyes. This means the method is gentle on cells and adequate for long-term observations, holding potential for testing and quality control applications in the pharmaceutical and biotechnology industries. The findings are published in the journal Nature Communications.

Microscopes have played a pivotal role in the development of science since the 16th century. However, progress has required not only more sensitive and accurate equipment and analysis, but also more specialized ones. Therefore, modern, cutting-edge techniques have had to straddle tradeoffs. Quantitative phase microscopy (QPM) leverages forward-scattered light and can detect structures at the microscale (in this study, over 100 nanometers), but not smaller. Consequently, this technique has been primarily used to take static pictures of relatively complex cell structures. Interferometric scattering (iSCAT) microscopy, on the other hand, exploits back-scattered light and can detect structures as small as single proteins. As such, it can be used to "track" single particles, allowing insight into dynamical changes within the cell, but it cannot provide the comprehensive view that QPM can.

"I would like to understand dynamic processes inside living cells using non-invasive methods," says Horie, one of the first authors.

Thus, the research team set out to investigate whether measuring both directions of light simultaneously could overcome the tradeoff and reveal a wide range of sizes and motions from the same image. To test the idea and confirm their newly built microscope was working as hoped, the researchers set out to observe what happened during cell death. They recorded one image encoding information from both forward and backward-traveling light.

Our biggest challenge was cleanly separating two kinds of signals from a single image while keeping noise low and avoiding mixing between them."

Keiichiro Toda, first author

As a result, they were able to quantify not only the motion of cell structures (micro) but also of tiny particles (nano). Additionally, by comparing the forward and back-scattered light, they could also estimate each particle's size and refractive index, a property describing how much light bends or scatters when passing through particles.

"We plan to study even smaller particles," Toda says, already thinking about future research, "such as exosomes and viruses, and to estimate their size and refractive index in different samples. We also want to reveal how living cells move toward death by controlling their state and double-checking our results with other techniques."

Source:
Journal reference:

Horie, K., et al. (2025). Bidirectional quantitative scattering microscopy. Nature Communications. DOI: 10.1038/s41467-025-65570-w. https://www.nature.com/articles/s41467-025-65570-w

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of AZoLifeSciences.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Intracellular Compounds Offer Blueprint for Next-Generation Targeted Therapies